How will the SSD6200 notify me if a RAID 1 array experiences a disk failure?

Written by Support Team

Updated at October 20th, 2021

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Tutorial Videos & Installation Guides
    SSD7000 Series
  • FAQ
    FnL Product Line Determining PCIe lane assignment for your SSD7000 Controller MacOS Windows Linux SSD6200 Series Controller SSD7000 Series Controller RocketStor Series RocketRAID Series RocketU Series Motherboard Compatible Report Other Questions Standard Responses for Known Issues or Subjects WebGUI eStore Gen5
  • HPT
    Product Support Video Installation Guides Shipping Troubleshooting Video Driver Installation Video
  • Compatibility Reports
    SuperMicro w/ HighPoint Compatibility HP w/ HighPoint Compatibility Dell w/ HighPoint Compatibility Asus w/ HighPoint Compatibility Gigabyte w/ HighPoint Compatibility
  • FAQ
    NVMe Products
  • Workaround Issue
+ More

When a RAID 1 array experiences a disk failure, the SSD6204/6202 will provide the following information:

 

1. RAID Status

The WebGUI will display a new icon and report the status as “Critical” under the Logical Tab (Logical Device Information):

 

Click “Maintenance” to view which disk has failed or dropped offline:

 

2. Event Notification

The WebGUI’s Event tab will display and record Warnings, Errors and Actions related to the NVMe SSD’s and RAID arrays.

The following screenshot displays two messages. The first message states “Plugging device detected. (disk at Controller1-Channel1)” – this  indicates that the SSD attached to channel/port 1 is faulty; it dropped offline and was later redetected by the SSD6204.

 

The message "Array ‘VD_0’ has been degraded" indicates that the RAID1 status is Critical.

 

3. Email Notification

You can configure the WebGUI to provide Email Notification – any events related to the NVMe SSD’s, RAID arrays or the controller will be emailed to the specified email address:

 

 

 

raid 1 ssd6202 ssd6204 critical raid failure failed disk dropped disk

Was this article helpful?

Yes
No

Related Articles

  • SSD6200 RAID Import Feature
  • Is the HP DL380 G9 Rackmount compatible with the SSD6204 NVMe RAID Controller?
  • Are HP ProLiant DL385 rackmount servers compatible with SSD6200/SSD7000/SSD7500SSD6540 Series NVMe RAID Controllers and Enclosures?

Copyright 2025 – HighPoint Technologies, Inc..

Knowledge Base Software by Helpjuice

Definition by Author

0
0
Expand