A brief introduction to the functions of the management software (WEBGUI)

Written by Support Team

Updated at January 8th, 2021

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Tutorial Videos & Installation Guides
    SSD7000 Series
  • FAQ
    FnL Product Line Determining PCIe lane assignment for your SSD7000 Controller MacOS Windows Linux SSD6200 Series Controller SSD7000 Series Controller RocketStor Series RocketRAID Series RocketU Series Motherboard Compatible Report Other Questions Standard Responses for Known Issues or Subjects WebGUI eStore Gen5
  • HPT
    Product Support Video Installation Guides Shipping Troubleshooting Video Driver Installation Video
  • Compatibility Reports
    SuperMicro w/ HighPoint Compatibility HP w/ HighPoint Compatibility Dell w/ HighPoint Compatibility Asus w/ HighPoint Compatibility Gigabyte w/ HighPoint Compatibility
  • FAQ
    NVMe Products
  • Workaround Issue
+ More

Selection of initialization method for creating RAID

Keep Old data

This initialization method is suitable for deleting RAID by mistake. The premise is that after you delete it by mistake, no disk has been written or the TRIM function takes effect. There is no read or write operation for the disk, just for data recovery.


Quick init

This creation method is only recommended to users for performance testing. There is no read operation for the disk, only a small part of the write operation. The data written is very small, usually at the end of the disk, used to verify the organization of the RAID, such as the basic information of the RAID, the capacity of the RAID, and which member disks are,etc. This operation has no effect on the disk.


Foreground(recommend)

Foreground will write 0 to the disk. Create redundant RAID, it is recommended to use this method for initialization. 

Background

The background reads first and then writes. The source disk is read and written to the verification disk.

 

Verify and Rebuilding

Verify

Check whether the source disk data is consistent with the target disk data. Only read comparison, no write operation. Assuming that the data is damaged, verify is used to detect whether the RAID is broken.

Rebuilding

Read the source disk, then write to the target disk. Rebuilding is established after verify fails. Rebuilding operation will cause performance degradation, this is unavoidable.

keep old date create raid background foreground quick init webgui function rebuilding verify

Was this article helpful?